PRODUCTS 




          







 


AIR CONDITIONING UNITS

Especially suited for mobile application suchas trucks, trailers, vans and shelters, whera rugged, dependable air conditioning unitis required.´

OPTIONS:
FILTERING
DEHUMIDIFYING
HUMIDIFYING
CIRCULATING

The series SAC Air Conditioning units are designed for use under severe operating conditions. Built to the highest performance standards, these commercial units include many features, materials and construction techniques found only in more expensive military-type Air Conditioners. Exclusive all-welded steel cabinet and conservative component selection provide a rugged, durable, easily maintained Air. Conditioning Unit which nish years of trwill furouble free service.

SAC units were originally designed as a simplified and economical version of Airflow CompanyÕs Military Air Conditioners.* Commercial and industrial acceptance of the SAC series has now made it possible to of fer these units as a standard item in Airflow CompanyÕ s growing line of air conditioning models.

Standard capacities and configuration are shown, oduce SAC units of any dimension and capacity to fit individual requiements

* (See MAC Series Technical Bullentin)

MODEL

TYPICAL
   REF.
STAGES

TYPICAL

DIMENSIONS

APPROX.
WEIGHT

 

AIR
QUANTITY

COOLING
100°F

CAPACITY
115°F

 H  

W

D

SAC-M- 18

1

24

48

24

500

600

1.5

1.3

-24

1

30

60

30

800

800

2.0

1.8

-36

1

38

76

24

1000

1200

3.0

2.7

-48

1

20

120

26

1100

1600

4.0

3.6

-60

1

24

120

26

1200

2000

5.0

4.5

-72

  1*

38

84

30

1300

2400

6.0

5.5

SAC-C- 36

1

36

36

36

800

1200

3.0

2.7

-48

1

36

36

36

900

1600

4.0

3.6

-60

1

40

40

40

1100

2000

5.0

4.5

SAC-FS- 18

1

48

36

24

800

600

1.5

1.3

-24

1

54

36

24

825

800

2.0

1.8

-36

1

60

36

24

900

1200

3.0

2.7

-48

1

66

40

24

950

1600

4.0

3.6

-60

1

72

40

24

1000

2000

5.0

4.5

-72

  1*

72

42

24

1200

2400

6.0

5.5

-84

2

72

72

24

1700

2800

7.0

6.4

-96

2

78

72

24

1800

3200

8.0

7.3

-108

2

78

78

24

2000

3600

9.0

8.2

-120

2

86

86

24

2300

4000

10.0

9.1

    *Single stage refrigeration unit for three phase power and two stage refrigeration units for single

      phase power.  Capacity based on 60 Hz. power supply.

APPLICATIONS

SAC-H  especially for spaces limited in height and width (ideal for trucks and vans), it can be mounted  between main frame member and outer skirt of the vehicle, or mounted on exterior wall of the van. A variety of supply and return air openings are available to fit  the individual application.

SAC-C  Designed for use where overall space is limited. Top or front discharge allows flexible installation  to meet space restrictions.

SAC-FS Designed to fit a variety of requirements from small to largest areas . Alternate discharge openings provide maximum locationing, FS model can be installed outside the van, etc., with use of flexible hose,  or as an interior-mounted  model. Some units are available in single or two stage configurations.

 

 

 

1-Weigth- Approximate weight of standard units, lbs.

2. Air quantity- At sea level and static pressure external of unit at 5”  water cage CFM

3. Cooling capacity – at ambient  conditions indicated, tons of refrigeration (one ton of refrigeration  is equal to 12,000  BTU per hour  cooling capacity) cooling capacity  based on air entering unit at 80ºF. dry bulb and 67º wet bulb  with air  quantity indicated  in chart.

4. Power Required – Most units are  available in  208, 220, 230, 440 volt, single or three  phase, 60 cycle power 50 Hz, also available.

High temperature  SAC units are available for special order  wich will deliver rated capacity @  125ºF. Standard SAC units  will operate  satisfactory in ambients up to  115ºF. but at reduced capacities

1.  Condenser  air discharge (protected by safety screen)

2.  Return air openings. *

3.  Supply air openings *

*single cooling stage unit normally has only one  return opening.

 

 

www.IMPACair.com      MIL SPEC TOUGH!